KB Article | Forcepoint Support

Notes & Warnings

Important Sidewinder Firewall will reach end of life on March 15, 2023. For more details, see the Product Support Lifecycle. For additional information on migration path to Forcepoint Next Generation Firewall, contact your local Forcepoint sales representative.

Problem Description

Environment

Firewall Enterprise 8.3.x MCV0X

Summary

This article contains important information about known issues of high or medium rating that are outstanding with this product release. This article will be updated if new issues are identified post-release or if additional information becomes available.
 
MCV VersionRelease to World (RTW)Release Notes
MCV06March 29, 2021https://www.websense.com/content/support/library/si/v83/relnote/si_83xmcv06_rn_a_en-us.pdf
MCV05May 18, 2017https://www.websense.com/content/support/library/si/v83/relnote/si_83xmcv05_rn_a_en-us.pdf
MCV04September 22, 2015PD26150
MCV03September 24, 2014PD25423
MCV02June 12, 2013PD24550

{GENRLS.EN_US}
Known Issues

CRITICAL: There are no critical issues at this time.
 
Non-critical:
 
Reference NumberRelated ArticleFound in MCV versionResolved in MCV versionIssue Description
 KB19841MCV06MCV06Issue:
  • The 8.3.MCV06 and current signatures take more memory than the previous engine version.
Resolution:
  • 8.3.MCV06 patch increases the memory limit from 512 MB per scanner to 700 MB per scanner.  Firewalls with smaller memory (4 GB or less) should be evaluated to see if a configuration change in the number of scanners may be needed.  For more information, see Knowledge Base article 19481.
882838 882831 MCV02/MCV03MCV04Issue:
  • When MCV02 is installed on Firewall Enterprise 8.3.x, the Engine Version is shown as 5400 instead of 5600. Also, when MCV02 is uninstalled the Engine will show as 5600 when it should show as 5400.
  • When MCV03 is installed on Firewall Enterprise 8.3.x, the Engine Version is shown as 5600 instead of 5700. Also, when MCV03 is uninstalled, the Engine Version will show as 5700 when it should show as 5600.
Workaround: Execute the following command through the command line interface (CLI): vscanupdate -I



Keywords: sidewinder; mcv release; known issues; resolved issues

Article Feedback